![](/images/folder/logos/medica100_logo.png)
Diatermo Βipolar 120 Watt Flash MB 120F
Mono bipolar electrosurgey unit 120W, Flash type for minor and major surgery procedures.
- Description
Description
Diatermo MB120 Flash - mono-bipolar 120 Watt
MB Flash is a high frequency electrosurgical equipment suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations.
MB Flash allows surgical treatments with programmable timer operations up to milliseconds or with the classic traditional mode.
MB Flash allow pure CUT, cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and BIPOLAR coagulation.
Digital reading of delivered power and the surveillance through microcontroller of the operational functions, assure absolute reliability of the working conditions.
MB Flashallow a highly professional surgery through ergonomic and safety features. Connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. Possibility to control the output functions and the delivery of output power by handle, allows surgical operation without diverting attention from the surgical field.
Features:
Patient to plate contact control
Split return electrode use allowed
Minimally invasive surgical treatment allowed
Monopolar and Bipolar independent output
Auto Start/Stop in Bipolar Coag
Working condition planning
Power delivery by pedal and/or handle
Digital regulation and indication of the output power
Sound level control
Adjustable power increment
RF power pulse emission time setting
RF power pulse interval setting
Technical Specifications
Max output power CUT: 120 W-250 Ohm
Max output power BLEND: 90 W-200 Ohm
Max output power ENHANCED: 90 W-250 Ohm
Max output power FORCED COAG: 80 W-150 Ohm
Max output power SOFT COAG: 60 W-100 Ohm
Max output power BIPOLAR COAG: 60 W-50 Ohm
Working frequency: 600 KHz
RF power pulse emission time: 10 ms - 30 sec.
RF power pulse interval: 1 - 9
Patient circuit: F
Selectable input voltage: 115 - 230 Vac
Mains frequency: 50 - 60 Hz
Electrical input power: 300 VA
Size WxHxD mm: 370 x 144 x 319
Weight: 6 kg
Controls: Patient/Plate circuit monitoring, Output power monitoring, auto check control
Safety: EN60601-1, EN60601-1-2, EN60601-2-2
Electrical Class: I CF, MDD 93/42/EC Class: II b
Standard accessories
MB two-button autoclave handle
Waterproof MB footswitch
MB flat neutral plate with cable
2 disposable ground pads
Kit 10 short standard electrodes diameter 2.4 mm
3 needles + 3 blades + 3 ball electrodes 7 cm
Power cable 5m
Microsurgery handle
Microsurgery needles 10 pieces
Medical device, Class: II B