UPS HW NRG PRO TOWER 10KVA/9000W UPS HW NRG PRO TOWER 10KVA/9000W
UPS HW NRG PRO TOWER 10KVA/9000W

UPS HW NRG PRO TOWER 10KVA/9000W

Code: 11339
Manufacturer Ref: UPS.NRG.0036
3.075,20 €
(2.480,00 € + VAT)
Availability:
Temporarily unavailable
Delivery time: Delivery 1 to 3 days



print product to pdf
print product to pdf
  • Description

Description

Blank page

UPS HW NRG PRO TOWER 10KVA/9000W
The UPS NRG PRO with On Line Double Conversion technology has DSP control, wide input voltage range for energy saving, eco mode and smart fan speed control (smart fan-speed control).
Its wide range makes it an ideal solution for a wide range of applications such as computers, servers, office equipment, computer systems of clinics and hospitals, banking equipment, factory equipment, IT equipment & telecommunication systems.

Specifications:
Graphic LCD Display with multifunction parameter settings
Charging/Rectifier/Inverter fully digital control technology
True On Line Double conversion with DSP control
Wide Input frequency range: (50Hz:45-55Hz /60Hz:54-66Hz)
Input current harmonic: < 3%
Low input current distortion
Economic Operation Mode (ECO)
Wide voltage range: 120VAC-276VAC
Self-Testing when UPS startup
Input over/under voltage protection
PFC Technology
Parallel Redundancy
Automatic Bypass
Cold Start (DC)
Fault isolation

INPUT:
Capacity: 10000VA/9000W
Phase: Single phase & Ground
Rated Voltage: 220/230/240Vac
Frequency range: 50Hz:45-55Hz; 60Hz:54-66Hz (Auto sensing)
Power Factor: >= 0,99
Bypass Voltage Range: Max voltage: +15% (optional +5%, +10%, +25%), Min voltage: -45% (optional -20%, -30%), Frequency protection range: +/-10%
ECO Range: same as the bypass
Harmonic Current:
<= 3% (100% non-linear load)

OUTPUT:
Phase: Single phase & Ground
Rated Voltage: 220/230/240VAC
Power Factor: 0,9
Voltage Precision: +/-1%
Output Frequency: 50/60 (+/- 0,1) Hz (Battery mode)
Crest Factor: 3:1
Transfer Time: 0 ms
Overload Capacity: Load <=
110%, 60min, <= 125%, last 10min, 150% last 1min, >=
150%, turn to bypass mode immediately
THD: <=
2%
Efficiency: ECO mode >=
98%, Normal mode >= 93,5%

BATTERY:
Voltage: +/-96V/ +/-108V/ +/-120V DC
Backup Time: Typical 10 min

COMMUNICATION INTERFACE:
RS232, Optical coupler dry contact, RS485, SNMP card (optional), Parallel card (optional), Centralized monitoring card

OPERATIONAL ENVIRONMENT:
Temperature: 0-40o C
Humidity: 0-95% non-condensing
Storage Temperature -25o C / 55o C
Altitude: up to 1500 m

OTHER:
Weight: 64 Kg
Dimensions: 250 (W) x 502 (D) x 616 (H) mm
Industry Standard: CE, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 60950-1, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8